Which states license sheet metal contractors as their own trade, which fold the work into an HVAC or mechanical license, and which set no state license at all.
Most states do not license sheet metal contracting on its own. A handful issue a dedicated sheet metal classification with its own exam, most fold duct work, flashing and metal roofing into the state's HVAC, mechanical or general contractor license instead, and a few states set no state level license for it at all.
At a glance
- Dedicated classifications: California (C-43), Nevada (C-13), Arizona (C-45, R-45, CR-45), Connecticut (SM-1 through SM-6) and Massachusetts (Board of Examiners of Sheet Metal Workers)
- Florida runs its own Division II sheet metal certificate, covered in full on our Florida sheet metal contractor license guide
- Most states have no separate sheet metal class; the work sits inside the HVAC, mechanical or general contractor license instead
- Washington and several others set no sheet metal license at all, only general contractor registration
This guide walks through where a standalone sheet metal license exists, what each one requires, and where the work instead rides on a broader license. For how contractor licensing works state by state outside this one trade, see our contractor license guide.
Two Models, and a Gap
Sheet metal licensing nationwide splits into three patterns, and the split does not track population or construction volume the way other trades do.
- A dedicated sheet metal classification. California, Nevada, Arizona, Connecticut, Massachusetts and Florida each issue a license or certificate that covers sheet metal work specifically, separate from the state's HVAC or mechanical credential.
- Sheet metal folded into a broader license. Most licensing states, Louisiana and North Carolina among them, cover duct fabrication and installation inside the HVAC, mechanical or general contractor license, with no separate sheet metal exam or class.
- No state level sheet metal license at all. Washington, Texas and Georgia set no statewide sheet metal credential; the work either falls under general contractor registration or is left to city and county rules.
Because a business searching "sheet metal contractor license" is usually trying to find out which bucket its state falls into, the table below sorts the states we could source by name, with the states covered in depth below it.
The State by State Table
Every row below was checked against the board, statute or administrative code on November 9, 2026.
| State | Sheet metal classification | Model |
|---|---|---|
| California | C-43 Sheet Metal Contractor | Dedicated, CSLB |
| Florida | Certified or registered Sheet Metal Contractor | Dedicated, CILB |
| Massachusetts | Journeyperson and Master Sheet Metal Worker | Dedicated, separate board |
| Connecticut | SM-1 through SM-6 | Dedicated, DCP trade license |
| Nevada | C-13 Sheet Metal, plus C-21c under HVAC | Dedicated, plus HVAC subclass |
| Arizona | C-45, R-45, CR-45 Sheet Metal | Dedicated, ROC |
| Louisiana | Folded into Mechanical 6.1 and Building 1.11 | No dedicated class |
| North Carolina | Folded into the Heating Group license | No dedicated class |
| Washington | None; general specialty contractor registration | No state license |
| Texas | None statewide | City and county rules only |
| Georgia | None; specialty contractor exemption applies | No state license |
Notes on the table above:
- California's C-43 covers selecting, cutting, shaping, fabricating and installing sheet metal: cornices, flashings, gutters, leaders, pans, kitchen equipment, duct work, patented chimneys, metal flues and metal roofing systems.
- Nevada runs two doors into sheet metal: the standalone C-13 classification, and C-21c, a sheet metal subclassification sitting inside the C-21 refrigeration and air conditioning license for contractors whose sheet metal work supports HVAC installs.
- Arizona splits sheet metal the same way it splits most trades: C-45 for commercial work, R-45 for residential, and CR-45 for both, each covering sheet metal, cornices, flashings, gutters, leaders, pans, kitchen equipment, duct work and skylights.
- Connecticut runs six separate sheet metal codes rather than one: full scope contractor and journeyperson licenses (SM-1, SM-2), a residential and light commercial tier capped at 35 tons of cooling or 14,000 cubic feet per minute (SM-3, SM-4), and a hood systems tier for commercial kitchen exhaust (SM-5, SM-6).
- Louisiana has no classification simply called Sheet Metal. Duct work sits under Mechanical subclassification 6.1, Heat, Air Conditioning, Ventilation, Duct Work and Refrigeration, while architectural and structural sheet metal sits under Building Construction subclassification 1.11, Roofing and Sheet Metal, Siding.
- Washington has no individual sheet metal worker certification currently in force. A 1987 bill would have added one to Title 18 RCW, but no sheet metal chapter appears in the state's current Title 18 chapter list, so the business instead registers as a specialty contractor the same way it would for any other trade.
California's C-43 Sheet Metal Contractor
The Contractors State License Board issues the C-43 Sheet Metal Contractor classification under Title 16 of the California Code of Regulations, Division 8, Article 3, citing Business and Professions Code sections 7008 and 7059. A C-43 contractor selects, cuts, shapes, fabricates and installs sheet metal items: cornices, flashings, gutters, leaders, pans, kitchen equipment, duct work with its insulation, patented chimneys, metal flues and metal roofing systems.
CSLB applies its standard classification requirements to C-43 the same way it does to every other specialty: four years of journey level experience within the ten years before filing, the Law and Business exam plus the C-43 trade exam through PSI, a $450 application fee, and the board's $25,000 contractor bond before the license issues. For the broader California license system, see our California contractor license page.
Nevada and Arizona Split Commercial, Residential and Dual
Nevada's C-13 Sheet Metal classification, set out in NAC 624.300, lets a contractor fabricate and install sheet metal including cornices, flashings, gutters, leaders, downspouts, pans, food service equipment, ducts, louvres, patented chimneys, flues and metal roof systems, but it does not cover equipment using refrigeration as an integral part of the system. That carve out is why Nevada also runs C-21c, a sheet metal subclassification inside the C-21 refrigeration and air conditioning license, for sheet metal work tied directly to HVAC installs.
Nevada applies the same general requirement to C-13 that it applies board wide: at least four years of experience as a journeyman, foreman, supervising employee or contractor within the 15 years before filing, a nonrefundable $300 application fee, a $600 biennial license fee once approved, and a bond the board sets between $1,000 and $500,000 based on the requested monetary limit. See our Nevada contractor license page.
Arizona's Registrar of Contractors runs the same commercial, residential and dual pattern it uses for most trades. C-45 is the commercial Sheet Metal classification, R-45 the residential version, and CR-45 combines both scopes. Under Arizona Administrative Code R4-9-102, C-45 permits installing and repairing sheet metal, cornices, flashings, gutters, leaders, pans, kitchen equipment, duct work, skylights, patented chimneys, metal flues and metal roofing systems, and R4-9-104 defines CR-45 as the combined commercial and residential scope. See our Arizona contractor license page.
Connecticut's Six Sheet Metal Codes
Connecticut's Department of Consumer Protection licenses sheet metal work under the Heating, Piping, Cooling and Sheet Metal Work Examining Board, and it defines sheet metal work as the installation, erection, replacement, repair or alteration of ferrous or nonferrous ductwork systems. Rather than one contractor and one journeyperson code, the state runs three matched pairs.
SM-1 is the Limited Sheet Metal Contractor license and SM-2 its journeyperson counterpart (Connecticut titles every sheet metal tier "Limited"), covering ductwork systems of any size or type, excluding pneumatic conveyance systems. SM-3 and SM-4 cover residential and light commercial work only, capped at single air handling units of 35 tons of cooling or fans and blowers of 14,000 cubic feet per minute or less. SM-5 and SM-6 cover hood ductwork systems built to code standards, the exhaust side of commercial kitchens.
Each contractor tier requires two years as a licensed journeyperson or equivalent documented experience and training; each journeyperson tier requires completion of a registered apprenticeship or equivalent. The Occupational Trade License Application carries a $150 fee for a contractor license and $90 for a journeyperson license, with a $150 contractor renewal and $120 journeyperson renewal, and every license in this group expires annually on August 31.
Massachusetts Licenses Sheet Metal Through a Separate Board
Massachusetts has no single HVAC license; heating, cooling, piping and ductwork each sit with a different board. Sheet metal specifically runs through the Board of Examiners of Sheet Metal Workers, under 271 CMR 3.00 and M.G.L. c. 112, sections 237 through 251, a separate board from the one that licenses refrigeration technicians and pipefitters.
The ladder runs Apprentice, two journeyperson tiers and two master tiers. A Journeyperson Unrestricted (J-1) needs 8,000 hours of sheet metal work over no less than five years as a licensed apprentice, a board approved 750 hour journeyperson course, and a passing exam score. A Journeyperson Restricted (J-2) needs 4,800 hours over no less than three years plus a 450 hour course, but the restricted license only covers residential buildings of three stories or less and commercial projects of 10,000 square feet or less in buildings of two stories or less. A Master (M-1 or M-2) needs the matching journeyperson license plus either 2,000 hours under that license or a board approved 40 hour master's course.
All business entities performing sheet metal work, corporations, partnerships, LLCs and LLPs alike, must be licensed through the board, with a licensed Master Sheet Metal Worker tied to the business. Licenses renew every two years on the 28th day of the holder's birth month, with a $57 penalty for a late renewal. Massachusetts licenses refrigeration, pipefitting, gas fitting and oil burner work completely separately from sheet metal; for that full picture, see our Massachusetts HVAC licensing guide.
Florida Runs Its Own Sheet Metal Certificate
Florida's Construction Industry Licensing Board issues a statewide Sheet Metal Contractor certificate, defined by a material gauge rather than a building type: U.S. No. 10 gauge metal or lighter, plus substitute materials such as fiberglass duct board. A Florida general or building contractor cannot self perform this work; the statute requires it be subcontracted to a certified or registered sheet metal contractor.
That statute, the gauge threshold, the four experience routes into the exam, the fee schedule and the qualifier rule are all covered in depth on our Florida sheet metal contractor license guide, so this page will not repeat them here.
Where Sheet Metal Rides on a Broader License
Most licensing states never created a sheet metal specific trade exam. Louisiana is typical: duct fabrication and installation sits under Mechanical subclassification 6.1 (Heat, Air Conditioning, Ventilation, Duct Work and Refrigeration), while architectural sheet metal and metal roofing sit under Building Construction subclassification 1.11 (Roofing and Sheet Metal, Siding). Louisiana counts labor and materials together toward whichever threshold applies, and reaches subcontractors the same way it reaches primes: $50,000 for the Building Construction classification that holds subclassification 1.11, but $10,000, the lower threshold Louisiana sets for electrical, mechanical and plumbing work, for the Mechanical classification that holds subclassification 6.1.
North Carolina folds sheet metal duct work into its Heating Group licenses rather than issuing a separate credential. Which tier covers the duct work depends on the system: Heating Group No. 1 covers the ducts and mechanical equipment that go with a steam, vapor or hot water heating system, Heating Group No. 2 covers systems circulating conditioned air with a mechanical refrigeration capacity over fifteen tons, and Heating Group No. 3 covers direct heating or cooling systems, all licensed through the State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors under G.S. 87-21. This is the more common pattern nationally: a company doing duct and sheet metal work as part of an HVAC install usually needs the state's HVAC or mechanical license, not a separate sheet metal credential. Our HVAC contractor license guide covers that path in every state, and our HVAC qualifying agent guide covers how the qualifier rule works once that license is in hand.
States With No Sheet Metal License at All
Washington does not license sheet metal work as its own trade today. A 1987 bill, House Bill 1117, would have created a journeyman and specialty sheet metal worker certificate of competency under a new Title 18 RCW chapter, but no such chapter appears in the state's current RCW title list, and the Department of Labor and Industries instead registers a sheet metal business the same way it registers any other specialty contractor: a $15,000 bond, liability insurance and a registration fee, with no dedicated trade exam. See our Washington contractor license page for that registration process.
Texas issues no statewide general or specialty contractor license, sheet metal included; the Texas Department of Licensing and Regulation's program list covers specific trades such as air conditioning and electrical work, and sheet metal work outside those programs is governed at the city and county level. Georgia licenses residential and general contractors but exempts specialty contractors performing limited or specific trade work for an owner, as long as any other work on the job stays incidental under the statute's own percentage test.
How to Get a Sheet Metal Contractor License, Step by Step
- Find your state's model in the table above: a dedicated classification, folded into HVAC or mechanical, or no state license.
- In a dedicated state, confirm whether the scope you need is commercial, residential or both; Arizona, and Connecticut's residential tier, split on that line.
- Pick the qualifying individual. Every dedicated classification licenses the company through a named person: California's qualifying individual, Nevada's responsible managing employee, Arizona's qualifying party, or Massachusetts's licensed Master Sheet Metal Worker.
- Document the experience the board asks for: four years within ten years in California, four years within 15 years in Nevada, or the hour counts Connecticut and Massachusetts set by tier.
- Apply and pay the application fee: $450 in California, $300 in Nevada, $150 for a Connecticut contractor license.
- Pass the required exams: the Law and Business plus C-43 trade exam in California, the C-13 trade exam in Nevada, the C-45 trade exam in Arizona, or the board exam in Massachusetts and Connecticut.
- File the bond or insurance the state requires: a $25,000 bond in California, a bond set between $1,000 and $500,000 in Nevada.
- Where there is no dedicated classification, apply for the state's HVAC, mechanical or general contractor license instead, and confirm with the board that your scope of work is covered.
When a Sheet Metal Business Cannot Qualify on Its Own
A shop with skilled fabricators and a steady backlog does not always have one person who can personally clear the experience and exam bar a board sets, or it loses that person and cannot bid work that needs the classification. Every board above licenses the company through that one qualifying individual, whatever the state calls the role.
A qualifying agent QUALIFIES the company as an owner or a full time, W-2 employee who genuinely supervises the work, never a percentage of revenue deal or a per project arrangement. That structure lets a sheet metal business take on licensed work while an owner builds toward qualifying personally, or keeps a qualified employee in place while the company expands into a second state, work our contractor qualifier services and our licensing services in all 50 states both support. Learn more about what a qualifying agent is, or hire a qualifying agent for your sheet metal company directly.
Frequently Asked Questions
Do you need a license to be a sheet metal contractor?
It depends on the state. California, Nevada, Arizona, Connecticut, Massachusetts and Florida each issue a dedicated sheet metal license or certificate. Most other licensing states fold the work into the HVAC, mechanical or general contractor license instead, and a few states, Washington and Texas among them, set no statewide sheet metal credential at all.
What is a C-43 license?
The C-43 is California's dedicated Sheet Metal Contractor classification, issued by the CSLB. It requires four years of journey level experience within the last ten years, the Law and Business and C-43 trade exams through PSI, a $450 application fee and a $25,000 contractor bond.
Is sheet metal the same as HVAC licensing?
No, even in states that issue both. Nevada's C-13 explicitly excludes equipment that uses refrigeration as an integral part of the system, which is why the state runs a separate C-21c sheet metal subclassification inside its HVAC license for that overlap. Florida keeps sheet metal, mechanical and air conditioning as three entirely separate Division II categories.
Does Florida license sheet metal separately from mechanical and air conditioning?
Yes. Florida runs separate statewide categories for sheet metal, mechanical, Class A air conditioning and Class B air conditioning, and companies doing more than one usually hold more than one certificate or employ more than one qualifier. See our Florida sheet metal contractor license guide for the full statute and fee breakdown.
What states have no sheet metal contractor license at all?
Washington has no sheet metal specific certificate, only general specialty contractor registration. Texas issues no statewide license for the trade, leaving it to city and county rules, and Georgia exempts specialty contractors performing limited work under its own statutory test.
How much does it cost to hire a qualifying agent for a sheet metal license?
It depends on the state, the classification and the company's structure, so it is quoted privately after a call. Hire a qualifying agent to start that conversation.
Sources
Retrieved November 9, 2026 unless noted.
- CSLB, C-43 Sheet Metal Contractor classification detail
- CSLB, List of all fees (retrieved 2026-11-07, cross-checked today, unchanged)
- CSLB, Issuing my license (bond, examination) (retrieved 2026-10-16, cross-checked today, unchanged)
- Nevada Administrative Code 624.300, Classification C-13: Sheet Metal
- Nevada Administrative Code 624.380, Classification C-21, subclassification C-21c
- Nevada State Contractors Board, General requirements FAQ (4 years, 15 year window)
- Nevada State Contractors Board, License requirements
- Ariz. Admin. Code R4-9-102, C-45 Sheet Metal (azroc.gov returned a 403 error to automated retrieval today; Cornell mirror opened instead)
- Ariz. Admin. Code R4-9-104, CR-45 Sheet Metal (azroc.gov returned a 403 error to automated retrieval today; Cornell mirror opened instead)
- Connecticut DCP, Sheet Metal Licenses and Scope of Work
- Connecticut DCP, Heating, Cooling and Sheet Metal Work Licenses (fees, expiration)
- 271 CMR 3.01, Application and Licensing, Massachusetts Board of Examiners of Sheet Metal Workers (mass.gov's own regulation pages return an access error to automated retrieval; Cornell's mirror was used, the same source and figures our Massachusetts HVAC licensing guide verified on 2026-11-05)
- M.G.L. c. 112, Section 240, Examination of sheet metal worker applicants
- M.G.L. c. 112, Section 243, Fees for sheet metal worker licenses
- Mass.gov, Sheet metal worker consumer fact sheet (business entities must be licensed) (mass.gov returned an access error to automated retrieval today; content cross-checked today through search results quoting this page)
- Florida DBPR, Construction Industry Licensing Board
- Louisiana State Licensing Board for Contractors, Exams and Classifications (Mechanical 6.1, Building Construction 1.11)
- Louisiana State Licensing Board for Contractors, FAQ ($50,000 major/specialty threshold, $10,000 electrical/mechanical/plumbing threshold, subcontractors included)
- North Carolina State Board of Examiners of Plumbing, Heating and Fire Sprinkler Contractors
- N.C.G.S. 87-21, Heating Group No. 1, No. 2 and No. 3 definitions
- Washington L&I, Register as a contractor
- Washington State Legislature, Title 18 RCW chapter list (no sheet metal chapter currently in force)
- Texas Department of Licensing and Regulation, Programs licensed and regulated
- Georgia Code 43-41-17, specialty contractor exemption
If your company needs a sheet metal qualifier in any of the states above, or a license application built around your actual crew and backlog, call 615-219-2110 or start at hire a qualifying agent. Marshall Schofield and Jeremiah Jaskulski, both licensed general contractors, master electricians, master plumbers and master mechanical contractors, built The Licensing Company around placing qualifiers who actually run the work. For other trade licensing guides, see our resources page.
Disclaimer: This article is provided for educational and informational purposes only. It does not constitute legal advice, licensing guidance, or an offer of services. Licensing requirements vary by jurisdiction. For specific compliance questions, contact The Licensing Company for a confidential consultation.
Tell us the state and the trade. A member of the team calls you back.
We confirm what your board requires for your situation, then match a licensed qualifier who joins your company as a full time W-2 employee. Rather talk now? Call 615-219-2110.
Tell us your state and trade
A member of the team calls you back from 615-219-2110.